{"product_id":"uts5026a-26-5-ghz-performance-series-signal-analyzer","title":"UTS5026A 26.5 GHz Performance-Series Signal Analyzer","description":"\u003cstyle\u003e\n.ut-cat{color:#333;font-family:Arial,Helvetica,sans-serif;line-height:1.5;}\n.ut-cat h4{color:#1a1a1a;font-size:1.15em;margin:1.5em 0 .5em;padding-bottom:.25em;border-bottom:2px solid #ccc;}\n.ut-cat h2{color:#1a1a1a;font-size:1.25em;margin:1.2em 0 .4em;}\n.ut-cat h3{color:#222;font-size:1.05em;margin:1em 0 .3em;}\n.ut-cat p{margin:.6em 0;}\n.ut-cat ul{margin:.5em 0;padding-left:1.4em;}.ut-cat li{margin:.25em 0;}\n.ut-cat img{max-width:100%;height:auto;}\n.ut-cat table{border-collapse:collapse;width:100%;margin:.5em 0;}\n.ut-cat th,.ut-cat td{border:1px solid #ddd;padding:6px 10px;text-align:left;vertical-align:top;}\n.ut-cat td strong{color:#222;}\n\u003c\/style\u003e\n\u003cdiv class=\"ut-cat\"\u003e\n\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cdiv class=\"panel\"\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch1\u003eUNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUNI-T UTS5026A Performance-Series Signal Analyzer\u003c\/strong\u003e covers \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e in a single instrument, with \u003cstrong\u003e-163 dBm\/Hz displayed average noise level\u003c\/strong\u003e (typical, with the UTS5000A-P26 preamp option) and \u003cstrong\u003e-107 dBc\/Hz typical phase noise\u003c\/strong\u003e at 1 GHz, 10 kHz offset. Total absolute amplitude accuracy is \u003cstrong\u003e±0.40 dB at 50 MHz\u003c\/strong\u003e reference. RBW resolves from \u003cstrong\u003e1 Hz to 8 MHz\u003c\/strong\u003e and the analyzer captures up to \u003cstrong\u003e100,001 sweep points\u003c\/strong\u003e per trace.\u003c\/p\u003e\n\u003cp\u003eUTS5026A is built around three pillars: \u003cstrong\u003efrequency reach\u003c\/strong\u003e through the K-band ceiling at 26.5 GHz, covering all sub-6 GHz cellular and Wi-Fi bands plus 5G mmWave-adjacent spectrum, SATCOM downlinks, and microwave point-to-point links; a \u003cstrong\u003equiet front end\u003c\/strong\u003e with -163 dBm\/Hz typical DANL (P26 option) and -107 dBc\/Hz typical phase noise that resolves low-level spurs and characterizes oscillator skirts cleanly; and a \u003cstrong\u003emodular measurement library\u003c\/strong\u003e covering vector signal demodulation, I\/Q capture, EMI pre-compliance, 5G NR and LTE air-interface decoding, dedicated phase-noise measurement, and analog AM\/FM demodulation — each available as a no-expiration license unlock. Engineered for RF and microwave design teams, EMC pre-compliance benches, cellular and SATCOM development groups, and private-sector test labs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e spectrum measurement — covers sub-6 GHz, K-band, and microwave point-to-point bands in one instrument\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDANL: -163 dBm\/Hz typical\u003c\/strong\u003e (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW); -150 dBm\/Hz typical baseline (preamp off)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase noise: -107 dBc\/Hz typical\u003c\/strong\u003e at 1 GHz, 10 kHz offset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal absolute amplitude accuracy: ±0.40 dB at 50 MHz\u003c\/strong\u003e reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRBW: 1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e, plus 4, 5, 6, 8 MHz wide-band settings; selectivity \u0026lt;4.1 : 1 nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSweep points: up to 100,001\u003c\/strong\u003e per trace; counter resolution 0.001 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrace detectors:\u003c\/strong\u003e Normal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum safe input:\u003c\/strong\u003e +27 dBm average \/ +47 dBm peak (gated)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e15.6-inch 1920×1080 multi-touch HD capacitive display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional licenses:\u003c\/strong\u003e VSA (digital demod), I\/Q analyzer, EMI pre-compliance, 5G NR \/ LTE FDD \/ LTE TDD demod, AMA (analog AM\/FM), PNM (phase noise), AMK (advanced measurement kit), P26 (preamp gain)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterfaces:\u003c\/strong\u003e RF input (NMD 2.92 mm), 10 MHz Ext Ref In\/Out (BNC), Ext Trigger In (BNC, TTL), HDMI 1.4, USB-A 3.0 + USB-A 2.0 Host, USB-B 2.0 Device, LAN (VXI11)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree firmware updates\u003c\/strong\u003e and \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eUNI-T UTS5026A Detailed Features\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e9 kHz to 26.5 GHz Frequency Coverage\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe UTS5026A spectrum input covers \u003cstrong\u003e9 kHz at the low end and 26.5 GHz at the high end\u003c\/strong\u003e, spanning eleven internal LO frequency bands to maintain calibrated response across the full range. That single-instrument reach removes the need for separate analyzers when work moves between sub-6 GHz cellular spectrum, ISM and Wi-Fi bands, K-band SATCOM downlinks, point-to-point microwave links, and radar IF chains.\u003c\/p\u003e\n\u003cp\u003eFrequency span is selectable from 0 Hz (zero-span time-domain capture) to the full 26.5 GHz range. Sweep time runs \u003cstrong\u003e1 ms to 4,000 s for spans ≥10 Hz\u003c\/strong\u003e, and 1 µs to 6,000 s in zero span for capturing transient events. The 10 MHz internal reference (with ±3×10⁻⁸ temperature stability) ties measurements to a stable timebase, with external 10 MHz reference in\/out on rear-panel BNC for shared-clock instrument racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1720626350\/UTS5026A_4.jpg\" alt=\"UNI-T UTS5026A 26.5 GHz Performance-Series Signal Analyzer — front three-quarter product view\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eUTS5026A front panel with 15.6-inch multi-touch display, RF input (NMD 2.92 mm), and full benchtop instrument footprint.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eSensitivity for Low-Level Signal Detection (DANL -163 dBm\/Hz typ.)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eWeak-signal work — identifying low-level spurs in oscillator output, characterizing leakage from a shielded enclosure, capturing intermittent interference — is rate-limited by how far the analyzer’s own noise floor sits below the signal of interest. UTS5026A reaches \u003cstrong\u003e-163 dBm\/Hz typical DANL\u003c\/strong\u003e in the 20 MHz to 1.5 GHz band \u003cem\u003ewith the UTS5000A-P26 preamp option\u003c\/em\u003e, and \u003cstrong\u003e-160 dBm\/Hz typical\u003c\/strong\u003e across most of the analyzer’s mid-band range with preamp engaged. Without P26, baseline DANL runs \u003cstrong\u003e-145 to -150 dBm\/Hz typical\u003c\/strong\u003e mid-band — competitive for general spectrum work, but P26 is what unlocks the headline number.\u003c\/p\u003e\n\u003cp\u003ePreamp coverage extends from \u003cstrong\u003e100 kHz to 7.5 GHz\u003c\/strong\u003e on the low-frequency band and \u003cstrong\u003e100 kHz to 26.5 GHz\u003c\/strong\u003e on the high band. Maximum safe input is \u003cstrong\u003e+27 dBm average\u003c\/strong\u003e (input attenuation ≥20 dB, preamp on) and \u003cstrong\u003e+47 dBm peak\u003c\/strong\u003e for short-pulse work.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Sensitivity.png\" alt=\"UTS5026A DANL sensitivity floor showing -163 dBm\/Hz typical noise level with preamp option\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eDisplayed Average Noise Level reaches -163 dBm\/Hz typical (with UTS5000A-P26 preamp option, 20 MHz to 1.5 GHz, 1 Hz RBW).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003ePhase Noise (-107 dBc\/Hz typ.) for Clean Oscillator Characterization\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe local oscillator’s phase noise is the floor that limits how cleanly the analyzer can resolve close-in spurs, modulation sidebands, and reciprocal mixing artifacts on the device under test. UTS5026A specifies \u003cstrong\u003e-107 dBc\/Hz typical at 10 kHz offset\u003c\/strong\u003e from a 1 GHz carrier, with \u003cstrong\u003e-102 dBc\/Hz at 1 kHz\u003c\/strong\u003e, \u003cstrong\u003e-110 dBc\/Hz at 100 kHz\u003c\/strong\u003e, and \u003cstrong\u003e-132 dBc\/Hz at 1 MHz\u003c\/strong\u003e offset (typical, 1 kHz RBW, 10 Hz VBW, log-average over \u0026gt;50 acquisitions).\u003c\/p\u003e\n\u003cp\u003eFor RF designers characterizing PLL synthesizers, VCOs, and crystal oscillators, that envelope means close-in noise sidebands on the device under test sit above the analyzer’s own contribution rather than buried beneath it. The \u003cstrong\u003eUTS5000A-PNM Phase Noise Measurement option\u003c\/strong\u003e adds a dedicated measurement mode with logarithmic offset axes, jitter calculation, and integration limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-Phase_Noise.png\" alt=\"UTS5026A phase noise plot showing -107 dBc\/Hz typical at 1 GHz center frequency, 10 kHz offset\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eNominal phase noise at 1 GHz center frequency: -100 dBc\/Hz at 1 kHz offset, -107 dBc\/Hz at 10 kHz offset, -132 dBc\/Hz at 1 MHz offset (typical).\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRBW Resolution and Selectivity (1 Hz to 8 MHz)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eResolution Bandwidth selects from \u003cstrong\u003e1 Hz to 3 MHz in 10% steps\u003c\/strong\u003e (the standard 10:1 ratio family used across professional spectrum analyzers), plus dedicated \u003cstrong\u003e4, 5, 6, and 8 MHz\u003c\/strong\u003e wide-band settings for fast sweeps over wide spans. Bandwidth accuracy is \u003cstrong\u003e±1.0% (±0.044 dB) nominal\u003c\/strong\u003e from 1 Hz to 750 kHz.\u003c\/p\u003e\n\u003cp\u003eSelectivity (the −60 dB to −3 dB shape factor) measures \u003cstrong\u003e\u0026lt;4.1 : 1 nominal\u003c\/strong\u003e, which lets two adjacent unequal-amplitude carriers resolve cleanly without the smaller signal disappearing into the larger one’s skirt. Video bandwidth tracks the same range, and seven trace detectors cover both general-purpose and standards-specific measurement modes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993120\/UTS5000A-RBW.jpg\" alt=\"UTS5026A resolution bandwidth filter showing 1 Hz minimum to 8 MHz maximum settings\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eRBW: 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz wide-band settings.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e100,001 Sweep Points for Fine-Grained Frequency Analysis\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eSweep point count is configurable from \u003cstrong\u003e11 to 100,001 across all spans\u003c\/strong\u003e. At 100,001 points across a 1 GHz span, frequency resolution per trace bin is \u003cstrong\u003e10 kHz\u003c\/strong\u003e — tight enough to localize narrow-band interference, identify specific ITU channel allocations, and walk between adjacent regulatory mask boundaries without interpolation between coarse sweep bins.\u003c\/p\u003e\n\u003cp\u003eMarker resolution scales with the trace span and sweep-point count. A dedicated frequency counter mode tightens uncertainty further, with counter resolution at \u003cstrong\u003e0.001 Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727989435\/UTS5000A-ScanPoints.png\" alt=\"UTS5026A trace with 100,001 sweep points showing high-resolution frequency-domain detail\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eTrace acquisition supports up to 100,001 sweep points across any selected span.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eVector Signal Analysis and I\/Q Capture (UTS5000A-VSA + UTS5000A-I\/Q Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-VSA Digital Demodulation option\u003c\/strong\u003e adds a vector demodulation engine covering \u003cstrong\u003e2 MHz to 26.5 GHz carrier\u003c\/strong\u003e and the major digital modulation formats: \u003cstrong\u003eASK (2-ASK); FSK (2\/4\/8\/16); MSK (GMSK); PSK (BPSK, QPSK, OQPSK, 8PSK); DPSK (DBPSK, DQPSK, D8PSK, π\/4-DQPSK, π\/8-D8PSK); QAM (16, 32, 64, 128, 256)\u003c\/strong\u003e. Symbol rate ranges \u003cstrong\u003e1 ksps to 2.5 Msps\u003c\/strong\u003e, with EVM\/SNR statistics displayed alongside IQ constellation, eye, and time-domain views.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-I\/Q Analyzer option\u003c\/strong\u003e adds direct I\/Q capture and spectrum analysis at \u003cstrong\u003e9 kHz to 25 MHz analysis bandwidth standard (extended to 40 MHz with B40)\u003c\/strong\u003e, with a \u003cstrong\u003e14-bit ADC at 90 MSa\/s\u003c\/strong\u003e capturing up to 4,000,000 IQ sample pairs per acquisition. Window selection covers Flat-top, Uniform, Hanning, Gaussian, Blackman, Blackman-Harris, and Kaiser-Bessel shapes. Together, the two options form the foundation for waveform-level characterization of arbitrary digitally-modulated carriers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Air-Interface Demodulation (UTS5000A-NR \/ FDD-LTE \/ TDD-LTE Options)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor teams developing 5G New Radio infrastructure, LTE base-station components, or cellular-band devices, three dedicated demodulation licenses extend the analyzer into protocol-aware air-interface measurement: \u003cstrong\u003eUTS5000A-NR for 5G New Radio\u003c\/strong\u003e, \u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e, and \u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e. Each license is a standalone purchase.\u003c\/p\u003e\n\u003cp\u003eCombined with the analyzer’s 26.5 GHz frequency reach, the cellular licenses cover sub-6 GHz LTE and 5G NR FR1 deployments directly, plus 5G NR FR2 mmWave bands at 24.25–26.5 GHz. The instrument’s low phase noise and tight amplitude accuracy translate into clean EVM measurements on the device under test. License unlocks are no-expiration: once added, they remain on the instrument for the life of the unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMI Pre-Compliance to 26.5 GHz (UTS5000A-EMI Option)\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A-EMI Pre-Compliance Measurement option\u003c\/strong\u003e transforms the analyzer into a CISPR\/EN-class pre-compliance instrument with regulatory limit lines, quasi-peak and average detectors, and band-segmented scan modes. Measurement extends to the analyzer’s full \u003cstrong\u003e26.5 GHz ceiling\u003c\/strong\u003e, covering not just the traditional 30 MHz to 1 GHz radiated-emissions band but also the higher-frequency emissions from 5G transceivers, automotive radar, and microwave data links.\u003c\/p\u003e\n\u003cp\u003eThe companion \u003cstrong\u003eUTS-EMI01 near-field probes kit\u003c\/strong\u003e adds four probe heads spanning 30 MHz to 3 GHz at three resolution scales plus a 5 mm resolution probe to 2 GHz, for localizing radiating components on a populated PCB. Pre-compliance use moves EMI debugging earlier in the development cycle — before the formal test-house chamber visit, when board-level fixes are still cheap.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1727993123\/UTS5000A-EMI_Screen.jpg\" alt=\"UTS5026A EMI pre-compliance measurement screen with regulatory mask overlay and detector trace\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003eEMI pre-compliance measurement mode with regulatory limit lines, quasi-peak detection, and near-field probe support.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e15.6″ Multi-Touch HD Display and Serviceable Front End\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\n\u003cdiv class=\"product-box product-left\"\u003e\n\u003cfigure class=\"product-figure\"\u003e\n\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\" class=\"product-image-thumb\"\u003e\n\n\u003cfigcaption class=\"product-figcaption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-box product-right\"\u003e\n\u003cp\u003eThe front-panel display is a \u003cstrong\u003e15.6-inch 1920×1080 multi-touch capacitive TFT LCD\u003c\/strong\u003e — a deliberate departure from the 7-to-10-inch displays common at this frequency tier. Capacitive multi-touch supports drag-to-pan, pinch-zoom on traces, and gesture-based menu navigation, with the larger display real estate accommodating up to 4-window simultaneous layouts in the VSA and I\/Q modes. The instrument is built for serviceability over the warranty lifetime: a \u003cstrong\u003eremovable dust filter\u003c\/strong\u003e on the air inlet lifts out for cleaning, preventing the dust-accumulation failure mode that limits long-term reliability on cooled bench instruments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cspan class=\"lightbox-close\"\u003e×\u003c\/span\u003e\n\u003cimg src=\"https:\/\/res.cloudinary.com\/uni-t\/image\/upload\/v1706309659\/UTS5026A_Touch_Screen.png\" alt=\"UTS5026A 15.6-inch multi-touch capacitive display showing trace zoom and multi-window layout\"\u003e\n\u003cspan class=\"lightbox-caption\"\u003e15.6-inch multi-touch capacitive HD display with gesture support: drag, pinch-zoom, and trace expansion.\u003c\/span\u003e\n\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eRF and Microwave Design \/ R\u0026amp;D\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eFor RF and microwave design teams characterizing PLL synthesizers, mixer spurious products, amplifier compression, and front-end module performance, the UTS5026A’s 26.5 GHz reach with -107 dBc\/Hz typical phase noise gives the instrument the headroom to act as the reference measurement on the bench. The 100,001-point sweep resolution, ±0.40 dB amplitude accuracy at 50 MHz, and full SCPI\/LXI remote control make the analyzer a primary fixture in R\u0026amp;D characterization workflows.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003e5G NR and LTE Cellular Development\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eWith the UTS5000A-NR, FDD-LTE, and TDD-LTE demodulation licenses, the analyzer covers sub-6 GHz cellular bands plus 5G NR FR2 mmWave allocations in the 24.25 to 26.5 GHz range. Combined with the I\/Q analyzer’s 40 MHz (B40) analysis bandwidth, the instrument supports waveform-level evaluation of base-station transmitters, small-cell units, and cellular-band devices.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch3\u003eEMC Pre-Compliance and Production Test Labs\u003c\/h3\u003e\n\u003cdiv class=\"product-row\"\u003e\u003cdiv class=\"product-box product-left\"\u003e\n\u003cp\u003eProduction characterization labs and EMC pre-compliance benches use the UTS5026A’s combination of 26.5 GHz frequency ceiling, regulatory-grade amplitude accuracy, and the optional UTS5000A-EMI license to run pre-chamber scans across CISPR-band ranges and into 5G transceiver and radar emission bands. Free firmware updates plus no-expiration license unlocks keep the instrument current as standards evolve.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eAccessories \u0026amp; In the Box\u003c\/h2\u003e\n\u003ch3\u003eStandard Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower cord × 1\u003c\/li\u003e\n\u003cli\u003eUSB cable × 1 (UT-D14)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement option licenses (no-expiration unlock)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-NR\u003c\/strong\u003e — 5G New Radio (NR) demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-FDD-LTE\u003c\/strong\u003e — LTE FDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-TDD-LTE\u003c\/strong\u003e — LTE TDD demodulation analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-VSA\u003c\/strong\u003e — Digital demodulation (ASK\/FSK\/PSK\/QAM\/MSK\/DPSK) with EVM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-I\/Q\u003c\/strong\u003e — I\/Q analyzer (25 MHz \/ 40 MHz with B40 analysis BW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-EMI\u003c\/strong\u003e — EMI pre-compliance measurement to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMA\u003c\/strong\u003e — Analog AM\/FM demodulation, 2 MHz to 26.5 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-PNM\u003c\/strong\u003e — Phase Noise Measurement (dedicated mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-AMK\u003c\/strong\u003e — Advanced Measurement Kit (channel power, ACPR, OBW, T-power, harmonics)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS5000A-P26\u003c\/strong\u003e — Preamplifier gain option (unlocks -163 dBm\/Hz typ. DANL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRF cables and connector kits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUT-CK02 kit\u003c\/strong\u003e — RF cables and connectors: UT-W03-40GHz cable, UT-C04-40GHz adapter, UT-C03-18GHz adapter, UT-W03 SMA-SMB cable, UT-C01 SMA-N adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNear-field probes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUTS-EMI01 kit\u003c\/strong\u003e — Four near-field probes: NFP-3G-P1 (30 MHz–3 GHz, 10 cm range), NFP-3G-P2 (30 MHz–3 GHz, 3 cm range), NFP-2G-P3 (30 MHz–2 GHz, 5 mm resolution), NFP-3G-P4 (30 MHz–3 GHz, 2 mm resolution)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhat's the difference between the UTS5000A and the UTS3000A series?\u003c\/p\u003e\n\u003cp\u003eThe two analyzers target different work. The \u003cstrong\u003eUTS3000A series\u003c\/strong\u003e covers 9 kHz to 3.6 \/ 6 \/ 8.4 GHz with a \u003cstrong\u003ebuilt-in tracking generator and standard real-time spectrum analysis plus VNA capability (S11 + S21)\u003c\/strong\u003e; it’s the right choice when work involves stimulus-response measurements, real-time transient capture as a standard capability, and characterization below 8.4 GHz.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eUTS5000A (UTS5026A)\u003c\/strong\u003e is a measurement-only analyzer covering \u003cstrong\u003e9 kHz to 26.5 GHz\u003c\/strong\u003e with no tracking generator and no VNA. It targets work that needs \u003cstrong\u003efrequency reach above 8.4 GHz\u003c\/strong\u003e — K-band SATCOM, 5G NR FR2 mmWave bands, 24 GHz radar, microwave links — or the deeper option library covering 5G NR \/ LTE demodulation and dedicated phase-noise measurement that the UTS3000A doesn’t offer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eWhich capabilities are standard, and which require optional licenses?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e (included): swept and FFT spectrum analysis from 9 kHz to 26.5 GHz, with all the headline specifications — 1 Hz to 8 MHz RBW, 100,001 sweep points, ±0.40 dB amplitude accuracy at 50 MHz, -107 dBc\/Hz typical phase noise, the full trace-detector set, marker functions, and SCPI\/LAN\/USB remote control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional licenses\u003c\/strong\u003e (each sold separately, no-expiration unlock): UTS5000A-VSA (digital demodulation), UTS5000A-I\/Q (I\/Q analyzer), UTS5000A-EMI (EMI pre-compliance), UTS5000A-NR (5G NR demod), UTS5000A-FDD-LTE and UTS5000A-TDD-LTE (LTE demod), UTS5000A-AMA (analog AM\/FM demod), UTS5000A-PNM (phase-noise measurement), UTS5000A-AMK (advanced measurement kit), and UTS5000A-P26 (preamplifier gain — unlocks the -163 dBm\/Hz typical DANL specification).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eDoes the UTS5026A include a tracking generator or VNA function?\u003c\/p\u003e\n\u003cp\u003eNo. The UTS5026A is a measurement-only signal analyzer — it does not produce stimulus signals. There is no internal tracking generator, no VNA capability, and no S-parameter measurement function. For applications requiring stimulus-response measurements (filter characterization, antenna VSWR, S11 \/ S21), the UTS3000A series provides those capabilities up to 8.4 GHz with a built-in reflection bridge and tracking generator. For frequencies above 8.4 GHz, an external signal generator paired with the UTS5026A in receive-only mode is the typical configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eCan I add the UTS5000A-P26 preamplifier option later, after the original purchase?\u003c\/p\u003e\n\u003cp\u003eYes. All UTS5000A optional licenses, including the P26 preamplifier gain option, are \u003cstrong\u003eno-expiration license unlocks\u003c\/strong\u003e that can be added at any time after the original instrument purchase. The hardware to support each option is present in every shipping unit; the license unlocks the firmware functionality. Adding P26 after purchase requires no service-depot return.\u003c\/p\u003e\n\u003cp\u003eThat makes a typical procurement path practical: buy the base instrument, then add P26, VSA, I\/Q, or cellular demod licenses as the project mix evolves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq-item\"\u003e\n\u003cp class=\"product-faq-question\"\u003eIs the UTS5026A remotely programmable?\u003c\/p\u003e\n\u003cp\u003eYes. The UTS5026A supports a complete \u003cstrong\u003eSCPI command set\u003c\/strong\u003e covering every front-panel function, accessible over \u003cstrong\u003eUSB-B 2.0, LAN (VXI-11 over 10\/100\/1000 Base RJ-45)\u003c\/strong\u003e, and through the built-in WebServer interface for browser-based access. The full programming manual ships with the instrument, and the analyzer integrates into ATE racks running NI-VISA, Keysight IO Libraries, or any standards-compliant instrument-control framework, with LXI conventions for network discoverability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 26.5 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.000000 MHz, ±3×10⁻⁸ stability (20 to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRBW selectivity (-60 dB \/ -3 dB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4.1 : 1 (-60 dB \/ -3 dB, nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,001 (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms to 4,000 s (span ≥ 10 Hz); 1 µs to 6,000 s (zero span)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrigger types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree Run, External 1, External 2, Video, Periodic Timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp on, with UTS5000A-P26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-163 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDANL (preamp off, baseline)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-150 dBm\/Hz typ. (20 MHz to 1.5 GHz typ.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase noise (1 GHz, 10 kHz \/ 1 MHz offset)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-107 \/ -132 dBc\/Hz typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal absolute amplitude accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±(0.40 dB + frequency response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude accuracy at 50 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.40 dB at 50 MHz reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference level range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-170 dBm to +30 dBm, 0.01 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput attenuator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 dB, 2 dB steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum safe input (avg \/ peak \/ DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+27 dBm avg \/ +47 dBm peak (gated) \/ +16 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThird-order intercept (TOI, typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+16 dBm typ. (10 MHz to 2 GHz, preamp off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResidual spurious response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-90 dBm (200 kHz to 26.5 GHz, swept)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrace detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal, Peak, Sample, Negative Peak, Log Power Average, RMS Average, Voltage Average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of traces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6 inch, 1920 x 1080, Multi-touch capacitive TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRF input connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 mm male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExt reference in \/ out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz BNC: -5 to +10 dBm in \/ \u0026gt;0 dBm out, 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB \/ LAN \/ HDMI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-A 3.0 (front) + USB-A 2.0 (rear) Host; USB-B 2.0 Device; LAN (VXI11) 10\/100\/1000; HDMI 1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (±10%), 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature \/ humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to +40 °C; ≤90% RH below +35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e445 mm × 311 mm × 195 mm (W × H × D) \/ About 11 kg (24.3 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications \/ ECCN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, cETLus \/ 3A992.a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch4\u003eDocumentation\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/instruments.uni-trend.com\/download?cate=93\"\u003eUTS5026A Datasheet, User Manual, and Software\/Firmware Downloads\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eOptions \u0026amp; Accessories\u003c\/h4\u003e\n\n\u003cp\u003eIncluded in box:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePower cord\u003c\/li\u003e\n  \u003cli\u003eUSB2.0 printing cable\u003c\/li\u003e\n  \u003cli\u003eEnglish download guide\u003c\/li\u003e\n  \u003cli\u003emulti-language safety manual\u003c\/li\u003e\n  \u003cli\u003ecalibration report (COC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSoftware options (model number — description):\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUTS5000A-AMA — AM\/FM Analog Demodulation Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-AMK — Advanced Measurement Kit Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-EMI — EMI Pre-Compliance Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-FDD-LTE — FDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-I\/Q — I\/Q Analyzer Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-NR — NR demodulation analysis option for UTS5000A series\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-P26 — Preamplifier Gain Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-PNM — Phase Noise Measurement Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-TDD-LTE — TDD-LTE Demodulation Analysis Option\u003c\/li\u003e\n  \u003cli\u003eUTS5000A-VSA — Digital Demodulation Analysis Option\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Uni-Trend US","offers":[{"title":"Default Title","offer_id":48463071674609,"sku":"181200100024X","price":31499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0800\/0946\/2001\/files\/UTS5000_1_sq.jpg?v=1785554912","url":"https:\/\/shopmanu.com\/products\/uts5026a-26-5-ghz-performance-series-signal-analyzer","provider":"Manu","version":"1.0","type":"link"}